DT862 Three-phase Electric Watt-hour Meter
Description:
The DT862 three-phase electric watt-hour meter (four-wire) is designed to meet the latest IEC60521 standards for measuring active energy in three-phase four-wire alternating current power grids. Connection is direct or by instrument transformers. DT862 three-phase electric watt-hour meter has an average service life of 10 years and maximum overload capacity of 600%Ib.
Structure and Features of Three-phase Electric Watt-hour Meter:
1. Meter case
It meets the protection requirements set by protection class IP53 of IEC60529.
2. Terminals & Terminal block
Terminals:
The connection terminals are made of nickel-plated brass with features of high mechanical strength, good conductivity and corrosion-resistance.
Terminal block:
The terminal block is injection molded of heat- and fire-resistant Bakelite.
3. Rotor
The rotor shaft is turned of high strength aluminum alloy.
Electric Watt-hour Meter DT862-A
Electric Watt-hour Meter DT862-B
Electric Watt-hour Meter DT862-C
Electric Watt-hour Meter DT862-D
Electric Watt-hour Meter DT862-E| Name | Type | Accuracy (class) |
Rated voltage(V) |
Rated current(A) | Connection Mode |
| Three-phase four-wire active energy watt-hour meter | DT862 | 2 | 3×380/220 | 3×1(2), 3×3(6), 3×1.5(6) |
Input through current transformer |
| 3×5(20), 3×10(40), 3×15(60), 3×20(80), 3×30(100) |
Directly input | ||||
| DT864 | 1 | 3×1(2), 3×3(6), 3×1.5(6) |
Input through current voltage transformer | ||
| Three-phase three-wire active energy watt-hour meter | DS862 | 2 | 3×380 | 3×1(2), 3×3(6), 3×1.5(6) |
Input through current transformer |
| 3×5(20), 3×10(40), 3×15(60), 3×20(80), 3×30(100) |
Directly input | ||||
| 3×100 | 3×1(2), 3×3(6), 3×1.5(6) |
Input through current voltage transformer | |||
| DS864 | 1 | 3×380 | 3×1(2), 3×3(6), 3×1.5(6) |
Input through current transformer | |
| 3×100 | 3×1(2), 3×3(6), 3×1.5(6) |
Input through current voltage transformer | |||
| Three-phase four-wire reactive energy watt-hour meter | DX862 | 3 | 3×380 | 3×1(2), 3×3(6), 3×1.5(6) |
Input through current transformer |
| 3×100 | 3×1(2), 3×3(6), 3×1.5(6) |
Input through current voltage transformer | |||
| DX864 | 2 | 3×380 | 3×1(2), 3×3(6), 3×1.5(6) |
Input through current transformer | |
| 3×100 | 3×1(2), 3×3(6), 3×1.5(6) |
Input through current voltage transformer | |||
| Three-phase three-wire reactive energy watt-hour meter | DX865 | 3 | 3×380 | 3×1(2), 3×3(6), 3×1.5(6) |
Input through current transformer |
| 3×100 | 3×1(2), 3×3(6), 3×1.5(6) |
Input through current voltage transformer | |||
| DX863 | 2 | 3×380 | 3×1(2), 3×3(6), 3×1.5(6) |
Input through current transformer | |
| 3×100 | 3×1(2), 3×3(6), 3×1.5(6) |
Input through current voltage transformer |

DT862 Three-phase Electric Watt-hour Meter